How To Replace Thermocouple On Richmond Water Heater. Reconnect the pilot light supply line and the burner gas supply tube to the control center or gas valve. The thermocouple is part of the pilot assembly where one end is always in contact with the pilot flame while the other side is connected to the gas control valve.

SP20064 Rheem Thermocouple Replacement Kit
SP20064 Rheem Thermocouple Replacement Kit from www.famousdiscountwarehouse.com

Install the new one the same way that you removed the old one. Once the pilot feed pipes, burner feed pipes and thermocouple are disconnected from the gas control valve, simply lift the burner assembly from the bottom of the water heater and remove it. Detach the thermocouple from the burner.

Kit Ensures Safe And Reliable Operation.

Water heater thermocouple kit for gas water heaters. Turn the gas back on and follow the lighting instructions on the water heater. Once the pilot supply tube, burner supply tube, and thermocouple are disconnected from the gas control valve (see above), simply lift and remove the burner assembly from the bottom of the water heater.

The Gas Water Heater Thermocouple Is The Safety Element Designed To Inform A Gas Control Valve If The Pilot Flame Is On Or Off, And Open Or Close The Gas To The Main Burner.

Detach the thermocouple from the burner. The burner typically sits loosely—or under clips—in the burning chamber and just slides out. And labor costs will also affect the overall price of water heater replacement.

First, Shut Off The Gas Valve On The Water Heater And The Gas Valve On The Gas Line Near The Heater.

You can do this by pushing down on the burner supply pipe to loosen and free the. For clarity purposes the burner is not shown in the photo. Remove the water heater burner assembly.

If The Flame Is Out, The Thermocouple Will Prevent The Valve From Delivering Gas To The Burner.

Then push the thermocouple completely forward until it is seated against the pilot assembly bracket. Open your water heater’s gas supply line and plug the power cord of your unit if it has one. Because space is tight on the bottom side of the water heater, it is recommended that you remove the entire burner assembly and work on the thermocouple outside of the water heater body.

Open A Hot Water Faucet Or Lift The Handle On The Relief Valve To Admit Air To The Tank.

If playback doesn't begin shortly, try restarting. The thermocouple is usually mounted on the burner assembly located near the bottom of the water heater tank. On the bottom of the gas valve that is mounted on the water tank, undo the thermocouple nut and gas piping nut that goes to the burner assembly.